Part Number Hot Search : 
B3222BD1 BULT106D A178L15 BULT106D BC8IT AD5291 BR1010 BR1010
Product Description
Full Text Search
 

To Download MPM-20S-24 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MPM-20S Series
Universal Input, 20W Miniature, PC Mount AC/DC Power Supplies
Electrical Specifications
Key Features:
* 20W Output Power * Universal 85-264 VAC Input * EN 60950 Approved * Adjustable Output * Meets EN55022 B * >200 kHour MTBF * Compact PC Mount Case
Specifications typical @ +25C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter Input Voltage Range Input Frequency Input Current Inrush Current EMI Safety Ground Leakage Current Conditions Min. Typ. 85 120 47 See Model Selection Guide 115 VAC 16.0 230 VAC 30.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 230 VAC Max. 264 370 63 Units VAC VDC Hz A Pk 0.1 0.3 Max.
mA Units
Output
Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide 2.0 0.5 See Model Selection Guide 50 115 VAC 20 230 VAC 80 0.02 Continuous (Autorecovery) Typ. 110% of Output Power Conditions Input to Output Input to Ground Output to Ground Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 1,500 500 Typ.
%
mV Pk - Pk mSec %/C
General
Parameter Isolation Voltage EMI/RFI EMC Compliance Switching Frequency Max. Units VAC
EN 55022 Level B IEC/EN 61000-4-2 Level 3 IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 150 kHz Min. -25 Typ. +25 Units C C C %
Environmental
Parameter Conditions
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight
Max. +70 +90 -25 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 85 Ambient Case
2.75 x 1.88 x 0.92 Inches (70.0 x 48.0 x 23.5 mm) Non-Conductive Black Plastic (UL94-V0) 5.65 Oz (160g) Conditions Min. Typ. MIL HDBK 217F, 25C, Gnd Benign 200 IEN 60950, IEC 60950 IEN 60950, IEC 60950 Max. Units kHours
Reliability Specifications
Parameter MTBF Safety Standards Safety Approvals
www.micropowerdirect.com
Model Selection Guide
Model Number MPM-20S-03 MPM-20S-05 MPM-20S-12 MPM-20S-15 MPM-20S-24 Input Current (A) 115 VAC 0.33 0.33 0.33 0.33 0.33 230 VAC 0.18 0.18 0.18 0.18 0.18 Voltage
(VDC)
www.micropowerdirect.com
Output 1 (Vout 1) Current (A) Load Typ. Reg. 4.10 1.0% 3.50 1.0% 1.60 1.0% 1.30 1.0% 0.85 1.0% Over Volt. Protection
(VDC)
Efficiency
(%, Typ)
3.3 5.0 12.0 15.0 24.0
6.5 6.5 20.0 20.0 30.0
82 82 82 82 82
Dual & Triple Output Models Are Available. For more information, contact the factory: sales@micropowerdirect.com
Notes: 1. Load regulation is measured for an output change of 10% to 90% at nominal input line. For multiple output models, the loads are balanced. 2. As shown in the connection diagram at right, a simple external circuit may be used to adjust the power supply output 10%. To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and the Vout trim pin. To adjust the output UP, connect a 5%, 3W resistor between the minus output pin and the Vout trim. Contact the factory for resistor values needed to achieve a specific output. 3. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-20S series, a 3.15A/250 VAC slow blow should be used.
Derating Curve
Mechanical Dimensions
Typical Connection
Typical Component Values
Vout 3.3 5.0 12.0 15.0 24.0 C1 330 F/16V 330 F/16V 220 F/25V 220 F/25V 220 F/35V C2 Fuse TVS P6KE6.8A P6KE6.8A P6KE16A P6KE20A P6KE33A
0.01 F/25V
3.15A/ 250 VAC
Pin Connections
Pin 1 2 3 4 8 Trim Function AC-Ground AC-Neutral AC-Line -Vout +Vout Trim
Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
Notes: 1. C1 is a high frequency, low resistance electrolytic capacitor. Refer to the suppliers specifications for capacitance/current ratings. 2. Voltage derating on all capacitors should be 80% or higher. 3. C2 eliminates high frequency noise. 4. The power supply includes an internal TVS. If the user requires a tighter OVP threshold, an external TVS may be connected as shown.
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
*
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of MPM-20S-24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X